Purpose of the Heat Pump

2.1 Application

The air-to-water heat pump is to be used exclusively for the
heating of heating water. It can be used in newly built or previ-
ously existing heating systems.
The heat pump is suitable for mono energy and bivalent opera-
tion down to an external temperature of -20 °C.
Proper defrosting of the evaporator is guaranteed by maintain-
ing a heating water return flow temperature of more than 18 °C
during continuous operation.
The heat pump is not designed for the increased heat con-
sumption required when a building is being dried out. The addi-
tional heat consumption should be met using special devices
provided by the customer. If a building is to be dried out in au-
tumn or winter, we recommend installing an additional heating
element (available as an accessory).
NOTE
The device is not suitable for operation with a frequency
converter.

2.2 Operating Principle

Outside air is drawn in by the ventilator and fed via the evapora-
tor (heat exchanger). The evaporator cools the air, i.e. it extracts
heat from it. This extracted heat is then transferred to the work-
ing medium (refrigerant) in the evaporator.
The heat is "pumped" to a higher temperature level by in-
creasing its pressure with the aid of an electrically driven com-
pressor. It is then transferred to the heating water using the liq-
uifier (heat exchanger).
Electrical energy is used to raise the temperature of the heat in
the environment to a higher level. Because the energy ex-
tracted from the air is transferred to the heating water, this type
of device is called an air-to-water heat pump.
The air-to-water heat pump consists of the main components
evaporator, ventilator and expansion valve, as well as the low-
noise compressor, liquifier and electrical control system.
At low ambient temperatures, humidity accumulates on the
evaporator in the form of frost reducing the transfer of heat.
Uneve accumulation during this process does not indicate a
fault.The evaporator is defrosted automatically by the heat
pump as required. Steam may be emitted from the air outlet de-
pending on the atmospheric conditions.
www.glendimplex.de
3

Scope of Delivery

3.1 Basic Device

The compact heat pump is supplied complete with all of the im-
portant components of the heating circulation system:
Expansion vessel
Heat circulating pump
Overflow valve and safety components (pressure relief
valve, pressure gauge)
The refrigeration circuit is "hermetically sealed" and contains
the fluorinated refrigerant R410A included in the Kyoto proto-
col. Information on the GWP value and CO
refrigerant can be found in the chapter Device information. The
refrigerant is CFC-free, non-ozone depleting and non-combus-
tible.
1)
Evaporator
2)
Ventilator
3)
24 l expansion vessel
4)
Switch box
5)
Liquifier
6)
Compressor
7)
Overflow valve
8)
Heat circulating pump
9)
Buffer tank
10) Filter dryer
11) Inspection window
12) Expansion valve
452161.66.20a · FD 0106