Vetus ILTCONF38 Instructions D'installation Et Mode D'emploi page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
• Connection cover (3)
Position the connection cover (3) as shown
in the drawing and fit the nut (4).
• Connections
Already installed are the hose connections
(connections) for:
- filling (5),
- venting (6),
- fuel supply (7), 10 mm diameter
- fuel return (8) 10 mm diameter.
If desired, the 10 mm hose pillars can be re-
placed with 8 mm hose pillars (9).
Fit the supplied blind plug (10) if the fuel re-
turn connection is not used, see
• Sender for fuel level gauge
If desired, remove the cover (11) and install
a sender for the tank level gauge; always ap-
ply the gasket.
• Fuel supply for heating system, see
If desired, use the fuel return connection (8)
as a supply for a heating system. For the fuel
return connection, replace the blind plug
(12) with a hose pillar (9).
Check the tightness of all connections
before filling the tank
vetus® Connection kit for fuel tanks
A
B
n
!
ote
9
12
4
5
11
3
12
ENGLISH
A
10
8
B
6
8
10 mm
7
8 mm
15
040110.01
9