4.6
Install the level detection (➲ Fig. [9] ).
L Systems whose pump control is equipped with float switches do not have
control units and alarm probes. In this case, ignore steps which include the
word „control unit" or „probe".
▶ Install the alarm probe in the following position ➊:
▶ Clip the T1 protective tube to the horizontal holder.
▶ T2/T3 - Clip the protective tube to the riser pipe.
▶ Screw the alarm probe into the protective tube, route the cable
through the cable conduit.
▶ Install the level detection , heed connection lengths of the submersible
pressure switch ( ➲ Fig. [9]).
▶ Route the pressure hose at a constant upward gradient in order to avoid the
accumulation of condensation.
▶ Pull the cable(s) for level detection through the cable conduit.
▶ Seal the cable conduit airtight and watertight.
4.7
Control unit
▶ If there is a control unit available, attach and connect it according to the control
unit instructions.
✓ Installation of the system is completed