Commissioning

6
Priming
Settings
a) dynamic
Stroke length, minimum values
20
Commissioning
NOTICE
• If the gamma/ L was calibrated before the Flow Control
was installed it may be necessary to recalibrate the
gamma/ L after the installation.
• The Flow Control cannot be used as a stop element.
The adjustment knob cannot be used to stop the bore
hole for the float.
IMPORTANT
If the pump goes into "Error" mode during commissioning,
acknowledge by pressing the P-key.
prime (press the two arrow keys on the pump together)
turn the control knob in both directions while filling the Flow Control
(to speed up venting)
NOTICE
Take into account the minimum values for the stroke length
and the maximum viscosity for the metering chemical!
Pump type
medium
gamma/ L ... Operating
pressure
1000
5 bar
1601
8 bar
1602
8 bar
1005
5 bar
0708
4 bar
1605
8 bar
1008
5 bar
0413, 0713,
-
0220, 0420,
-
0232
-
stroke length
length max.
(scale
Operating
divisions)
pressure
> 50 %
10 bar
> 30 %
16 bar
> 30 %
16 bar
> 30 %
10 bar
> 30 %
7 bar
> 30 %
16 bar
> 30 %
10 bar
> 30 %
-
> 30 %
-
> 30 %
-
stroke length
(scale
divisions)
> 60 %
> 40 %
> 40 %
> 50 %
> 40 %
> 50 %
> 40 %
> 30 %
> 30 %
> 30 %