The "Flow Control" flow monitor is designed for gamma/ L series metering
pumps with plastic liquid ends. It can be fitted directly onto the liquid end.
The flow monitor is supplied ready fitted with a connection cable.
It is used for monitoring the flow volume pulses of the dosing pump in
accordance with the float and orifice principle. The proportion of metering
chemical flowing past the float is adjusted with the adjusting screw to match
the pre-set lift volume of the pump so that an alarm is given if the feed rate
falls by approx. 20 %.
On the gamma/ L the maximum admissible number of incomplete strokes
can be pre-set to between 1-127, allowing optimum adaptation to process
requirements.
2
• The Flow Control is designed exclusively to feed back to a gamma/ L
• The Flow Control can be screwed directly (without adapter) onto liquid
• All other uses or modifications are prohibited!
• The Flow Control cannot indicate a burst in the pump discharge line.
• The Flow Control must be operated by trained personnel.
• Observe the relevant national directives throughout the service life phases
• You must observe the information in the operating instructions manual on
3
Admissible storage temperature:
Humidity:
ProMinent
®
About this product / Safety / Storage and transport

About this product

Safety

series pump the pulses of liquid metering chemical created by the pump.
If there is no acknowledgement pulse the Flow Control thereby indicates
that no medium is being metered (due to blocked pump priming or
discharge line, empty chemical feed tank, air in the liquid end, ...).
ends made of plastic only.
All other activities must be carried out by appropriately trained and
authorised personnel!
of the equipment!
the different service life phases of the equipment!

Storage and transport

-10 ºC to +50 ºC
98 % rel. humidity, non condensing
17