6.5.2.
Use in temperature class T6
Ignition protection type Ex ia, Gas group II C
Temperature
Max. per-
class
mitted
ambient tem-
perature [°C]
-40 ... +60
-40 ... +55
-40 ... +50
-40 ... +45
T6
-40 ... +40
-40 ... +60
-40 ... +55
-40 ... +50
The maximum permitted power depends on the max.
ambient temperature, the temperature class and the
installation.
10
Assembly
Max. per-
mitted power
consumption
[W]
0.4
0.5
Block
0.7
assembly
0.9
1.1
0.7
Individual
0.9
1.1
english
PTB 01 ATEX 2175
Technical data
6.5.3.
Use in temperature class T5
Ignition protection type Ex ia, Gas group II C
Temperature
Max. per-
class
mitted
ambient tem-
perature [°C]
-40 ... +75
-40 ... +70
-40 ... +65
-40 ... +60
T5
-40 ... +55
-40 ... +75
-40 ... +70
-40 ... +65
6.5.4.
Use in temperature class T4
Ignition protection type Ex ia, Gas group II C
Temperature
Max. per-
class
mitted
ambient tem-
perature [°C]
T4
-40 ... +100
Assembly
Max. per-
mitted power
consumption
[W]
0.4
0.5
Block
0.7
assembly
0.9
1.1
0.7
Individual
0.9
1.1
Assembly
Max. per-
mitted power
consumption
[W]
Block
0.7
assembly