Digital Temperature Controller
Single and dual shelved units may be equipped with an optional
digital temperature controller that regulates and displays the
base temperature(s). Use the following procedures to operate
the digital temperature controller.
NOTE: This option is factory-installed only, not available for
retrofit.
NOTE: Units manufactured for use outside the United States
and Canada will have digital temperature controllers
that indicate temperature in Celsius (°C).
"out 1"
SET
Down Arrow
Key
Key
Digital Temperature Controller
1. move the unit Power ON/OFF (I/O) toggle switch(es) to the
ON position.
• The digital temperature controller will energize and the
current temperature of the heated base(s) will appear
on the display. CAuTION: Some exterior surfaces on
the unit will get hot. use caution when touching
these areas.
• The phrase "out 1" will appear in the upper left corner of
the display to show that the base is in heat mode.
2. Press and release the
temperature will be shown on the display and "out 1" will
flash in the upper left corner.
3. Press the
key or
change the setpoint temperature. If no key is pressed within
15 seconds, the display will revert to the current
temperature of the heated base(s)
4. Press the
key or wait 15 seconds to lock in the new
setpoint temperature. The setpoint temperature range of
the controller is from room temperature to 185°F (85°C).
Locking/unlocking the Digital Temperature
Controller
The keys on the digital temperature controller can be locked to
prevent unauthorized changes to the settings.
To lock the keys of the digital temperature controller:
• Press and hold both the
same time for over two seconds. The message "Loc" will
appear on the display.
To unlock the keys of the digital temperature controller:
• Press and hold both the
same time until the message "UnL" appears on the display.
Form No. GR2SDm-0316
Fahrenheit
Symbol
Up Arrow
Key
key. The current setpoint
key within 15 seconds to
key and
key at the
key and
key at the

OPTIONS AND ACCESSORIES

Halogen Display Lights
Optional halogen display light bulbs can be ordered in place of
the standard incandescent display light bulbs for domestic
models only.
Stainless Steel Divider Rods
additional stainless steel divider rods are available to help keep
product separate in the channels.
Designer Inset Color Panels
Choose from several Designer colors to coordinate the inset
panels on the merchandising warmer to surrounding decór.
NOTE: This option is factory-installed only, not available for
retrofit.
Sneeze Guards
Sneeze guards are available as options. GR2SDH models can
be fitted with sneeze guards above each shelf on both sides of
the unit. GR2SDS models can be fitted with sneeze guards
above each shelf on the customer side of the unit only. Use the
following procedure to install sneeze guards.
NOTE: This option is factory-installed only, not available for
retrofit.
1. Remove protective paper from all surfaces.
2. Slide the sneeze guard into the channel on the unit and
align the holes on the sneeze guard with the screw holes
in the channel.
3. Insert the thumbscrews from the top side of the channel,
through the sneeze guard, and out through the bottom of
the channel.
4. Place the cap nuts on the thumbscrews and tighten until
snug. Do not over-tighten the nuts.
Cap Nut
Channel
Installing a Sneeze Guard
Fixed Front Glass Guards
Fixed front glass guards are available as options for all
GR2SDH models. This option converts the unit to a server only
merchandising warmer.