Erreka CICLÓN Manuel De L'installateur page 54

Actionneur électromécanique pour portes battantes
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION
EPS1 card brake connection
A1, A2: operators
FR2
FR1 connections (A1 brake)
If the operator DOES NOT have an encoder:
COM white wire
L1
red wire
If the operator HAS an encoder:
COM orange wire
L1
purple wire
Fig. 8
EPS1 plate brake connection
50
Installation Manual
If the operator to be installed has a brake, the EPS1 plate must be used to connect
it to the VIVO-M203 board, carrying out the connections indicated below.
M203: 230V/50Hz
FR1
DL1
DL2
F1
COM
L1
L2
VIVO-M203
FR2 connections (A2 brake)
If the operator DOES NOT have an encoder:
COM white wire
L2
red wire
If the operator HAS an encoder:
COM orange wire
L2
purple wire
Red LED, FR1 activation
Green LED, FR2 activation
EPS1
P249Y

Publicité

Table des Matières
loading

Table des Matières