Mounting and
operating instructions
Electrical installation
Warning: Pin 1 and pin 5 must not be connected to operational voltage as this will destroy the
device.
Turn the sensor connector plug according to the installation position (Illustr. 1 page 3) so that the connection cable
can be freely connected without being bent.
Insert the socket of the connection cable into the device connector and screw tight
For example, secure the connection cable from sliding with a cable tie .
Connect the sensor as shown in Illustr. 8
2
BN
1
WH
5
GY
6
PK
8
RD
4
YE
GN
3
7
BU
PNP
Illustr. 10
15400127
Connection
Colour
1 (WH)
White
2 (BN)
Brown
3 (GN)
Green
4 (YE)
Yellow
5 (GY)
Grey
6 (PK)
Pink
7 (BU)
Blue
8 (RD)
Red
Once power supply has been connected, the device is ready for operation after a short stand-by delay
(< 300 ms).
For maximum precision, please allow for a heating period (approx. 5 minutes).
3RG72563NQ00PF Distance sensor 06813787 / 453489 Stand: 03/2011
+U
B
1
5
Q A 4...20 mA
Q 2
PNP
Q 1 /IN
-U
B
Use
RS485 Y/A
+ U
B
As signal output Q
or input with optional input functions (see
1
"Settings" page 32)
or switching function "good target" (detec
As signal output Q
2
table object in measuring range)
RS 485 Z/B
Q
+ analogue measuring value
A
U
B
Q
analogue earth
A
Typ / Type / Ref.
3RG72563NQ00PF RS485 Y/A
Pin 1
Pin 5
RS485 Z/B
Comments
Q
1
Q
or good target
2
29