Mounting and
operating instructions
No. LED Muster Description
signal output shows status "good
10
Q
2
target". Switching signal can be inverted
with function no 8.
11
Q
= trigger input mode:
1
With rising edge on Q
held until the next trigger occurs.
12
Q
= enable input mode:
1
Used to switch laser beam on and off.
Laser beam is on when Q
= U
Last measured value remains. When re
activated, the response time is prolonged
according to the set mean value.
13
Switches off averaging:
The first measured value is taken into
account (page 35).
14
Switches on 4 ms averaging:
the first 10 meas. values are taken into
account (page 35).
15
Switches on 40 ms averaging:
all (max. 100) meas. values are taken into
account (page 35).
Set analogue output 0% (4 mA):
16
When S button is activated, the current
meas. value corresponds with 0% value of
the analogue output.
Set analogue output 100% (20 mA): When
17
S button is activated, the current meas.
value corresponds with 100% value of the
analogue output.
18
Q
automatic zero mode:
1
For characteristic curve displacement. If
Q
= +U
1
is set to the analogue value 0 % = 4 mA.
The incline of the characteristic curve is
maintained. If exceeded, the characteri
stic curve ends at the start or end of the
measuring range.
19
Q
automatic centre mode: displacement
1
of centre of characteristic curve. If Q
+U
B
the analogue value
50 % = 12 mA. The incline of the charac
teristic curve is maintained. If exceeded,
the characteristic curve ends at the start
or end of the measuring range.
* as long as the S button is pressed
3RG72563NQ00PF Distance sensor 06813787 / 453489 Stand: 03/2011
, measured value is
1
1
, the laser beam is switched off.
B
, the current measuring signal
B
, the current measuring signal is set to
"ZA" status indicator
On = Object within...
Off = Object outside...
On = Q
Off = Q
On = active
Off = not active
= +U
. If Q
B
1
On = Averaging off
On = active
Off = not active
On = active
Off = not active
On* = Object within...
Off* = Object outside...
...measuring range
On* = Object within...
Off* = Object outside...
...measuring range
On = Automatic zero active
Off = Autommatic zero not active
On = Automatic centre active
=
Off = Automatic centre not
1
active
...measuring range
is a trigger input
1
is not a trigger input
1
Factory setting
On
Off
Off
On
Off
Off
0% = 4 mA = end
of meas. range
100% = 20 mA
= start of meas.
range
Not active
Not active
33