Instructions Of Use; General Use - Pepperl+Fuchs 3RG7256-3NQ00-PF Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions of use

Control panel
The sensor has various modes and is configured using the S and T buttons.
Button
Set button:
Toggle button: Select a function (proceed to the next function)
The selected settings and signal condition are indicated by LEDs.
Illustr. 9
15500144
The table of functions on page 32 explains the further significance of the LEDs: Q

General use

The following four steps are used to configure the device:
1. Activate setting mode
Press the S and T buttons simultaneously for 3 seconds
After this period, the power supply indicator BA flashes
Set device, see Illustr. 9. The LEDs show the status of function no. 1 (page 32)
When all the LEDs start immediately flashing
 Unlock device, see paragraph "Unlocking keys" on page 34
2. Select functions (see page 32)
Press the T button to select the next function in the function table.
The function number is indicated by a clear LED pattern and the function status is indicated by the status indicator ZA
(LED on = active, LED off = not active).
The sensor only switches to the next function when the T button is released.
30
Change / confirm a setting or set a switching point
LED
Colour
BA
Green
ZA
Red
Q
Yellow
1
Q
Yellow
2
H
Green
OK
Green
T
Green
Z
Green
3RG7256­3NQ00­PF Distance sensor ­ 068­13787 / 45­3489 ­ Stand: 03/2011
Use/Description
Power supply indicator
On: ready (run mode)
Flashing: setting mode is active
Status indicator
Function activated/not activated, or confirmation signal
Q
input/output
1
Q
output
2
Q
trigger input or Q
enable input function active
1
1
Good target (object detected and in measuring range)
Pulse stretching function is active
Q
automatic centre or Q
1
Mounting and
operating instructions
automatic zero function is active
1
, Q
, H, OK, T and Z
1
2

Publicité