Ivoclar Vivadent Tetric EvoFlow Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
Additional notes
1. Tetric EvoFlow should have room temperature when applied.
2. If necessary, fresh Tetric EvoFlow can be directly applied to polymerized
material. If the material has already been polished, it must first be
roughened before fresh Tetric EvoFlow is applied.
Warning
– Unpolymerized Tetric EvoFlow should not come in contact with
skin/mucous membrane or eyes. Unpolymerized Tetric EvoFlow may
have a slight irritating effect and may lead to a sensitization against
methacrylates.
– Commercial medical gloves do not provide protection against the sensi-
tizing effect of methacrylates.
Storage
– Storage temperature: 2–28 °C / 36–82 °F.
– Close syringes/Cavifils immediately after usage. Exposure to light causes
premature polymerization.
– Shelf life: see note on Cavifils, syringes and packages.
– Do not use Tetric EvoFlow after the indicated date of expiration.
– Do not use oxidizing disinfectants to disinfect syringes and Cavifils.
If Tetric EvoFlow is applied from the Cavifil directly into the oral
cavity of the patient, we recommend using the Cavifil only once
due to hygienic reasons (prevention of cross-contamination between
patients). The same applies to the application tips of syringes.
Keep the material out of the reach of children.
For use in dentistry only.
Date information prepared:
06/2010; Rev. 3
Manufacturer:
Ivoclar Vivadent AG, FL-9494 Schaan/Liechtenstein
This material has been developed solely for use in dentistry. Processing should be carried out
strictly according to the Instructions for Use. Liability cannot be accepted for damages
resulting from failure to observe the Instructions or the stipulated area of application. The
user is responsible for testing the material for its suitability and use for any purpose not
explicitly stated in the Instructions. Descriptions and data constitute no warranty of attrib-
utes and are not binding.
Tetric EvoFlow
Deutsch
Gebrauchsinformation
Beschreibung:
Tetric EvoFlow ist ein fliessfähiges, lichthärtendes, röntgenopakes Nanohy-
brid-Composite für die Füllungstherapie und die Zementierung von Keramik-
und Compositerestaurationen. Tetric EvoFlow härtet mit Licht der Wellen-
länge im Bereich von 400–500 nm (Blaulicht) aus.
Farben:
Tetric EvoFlow ist in folgenden Farben lieferbar:
Schmelzfarben
A1, A2, A3, A3.5, A4, B3
IVA5, IVA6
Hochtransparente Inzisalfarbe
T
Dentinfarben
A3,5 Dentin
Bleach-Farben
Bleach Extra Light (XL), Bleach Light (L), Bleach Incisal (I), Bleach Medium (M)
Zusammensetzung:
Die Monomermatrix besteht aus Dimethacrylaten (38 Gew.%). Die Füllstoffe
bestehen aus Bariumglas, Ytterbiumtrifluorid, hochdispersem Siliciumdioxid,
Mischoxid und Copolymer (62 Gew.%). Zusätzlich enthalten sind Additive,
Katalysatoren, Stabilisatoren und Pigmente (< 1.0 Gew.%).
Der Gesamtgehalt an anorganischem Füller beträgt 57.5 Gew.% bzw.
30.7 Vol.% . Die Partikelgrösse der an-organischen Füllstoffe liegt zwischen
40 nm (0.04 µm) und 3000 nm (3 µm) bei einer mittleren Korngrösse von
550 nm (0.55 µm).
Indikation:
– Als erste Schicht bei Füllungen der Klassen I bis V
– Frontzahnfüllungen (Klassen III, IV)
– Füllungen der Klasse V (Zahnhalskaries, Wurzelerosionen, keilförmige
Defekte)
– kleine Füllungen jeglicher Art
– Erweiterte Fissurenversiegelung
– Verblockung gelockerter Zähne
– Ausblocken von Unterschnitten
– Adhäsive Befestigung von lichtdurchlässigen indirekten Composite- oder
Keramik-Restaurationen
– Reparatur von Composite-/Keramikverblendungen
®

Publicité

Table des Matières
loading

Table des Matières