Korg electribe 2 Manuel De L'utilisateur page 72

Masquer les pouces Voir aussi pour electribe 2:
Table des Matières

Publicité

+----------------+--------------------------------------------------+
PPpp : 0~FA = Pattern No. 001-250
 Receive this message & data, save them to Internal Memory and transmits
Func=23 or Func=24 message.
 Receive Func=1C message, and transmits this message & data from Internal
Memory.
 When DATA DUMP is executed, transmit this message & data from Internal
Memory.
7(7) GLOBAL DATA DUMP
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,23,
| ProductID (electribe)
| 0101 0001 (51) | GLOBAL DATA DUMP
| 0ddd dddd (dd) | Data
|
:
|
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
 Receive this message & data, save them to Internal Memory and transmits
Func=23 or Func=24 message.
 Receive Func=0E message, and transmits this message & data from Edit
Buffer.
 When DATA DUMP is executed, transmit this message & data from Edit
Buffer.
8(8) RECEIVE DATA FORMAT ERROR
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,23,
| ProductID (electribe)
| 0010 0110 (26) | DATA FORMAT ERROR
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
When found an error in the received message (e.g. data length), transmits
this message.
9(9) DATA LOAD COMPLETED (ACK)
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,23,
| ProductID (electribe)
| 0010 0011 (23) | DATA LOAD COMPLETED
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
When DATA LOAD,PROCESSING have been completed, transmits this message.
10(10) DATA LOAD ERROR (NAK)
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,23,
| ProductID (electribe)
| 0010 0100 (24) | DATA LOAD ERROR
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
Korg Electribe 2 (Sampler) - Aide-mémoire
Utilisation avancée - 2.2 Guide des paramètres du modèle « electribe 2 »
Description
:
Description
Description
Description
51H
(TABLE 7, NOTE 1,3) |
26H
23H
24H
Juin 2018
R/T
|
|
|
|
|
|
T
|
|
|
|
|
T
|
|
|
|
|
T
|
|
|
|
|
72/166