Korg electribe 2 Manuel De L'utilisateur page 105

Masquer les pouces Voir aussi pour electribe 2:
Table des Matières

Publicité

| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
PPpp : 0~FA = Pattern No. 001-250
 Receive this message & data, save them to Internal Memory and transmits
Func=23 or Func=24 message.
 Receive Func=1C message, and transmits this message & data from Internal
Memory.
 When DATA DUMP is executed, transmit this message & data from Internal
Memory.
19(7) GLOBAL DATA DUMP
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,24,
| ProductID (electribe sampler)
| 0101 0001 (51) | GLOBAL DATA DUMP
| 0ddd dddd (dd) | Data
|
:
|
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
 Receive this message & data, save them to Internal Memory and transmits
Func=23 or Func=24 message.
 Receive Func=0E message, and transmits this message & data from Edit
Buffer.
 When DATA DUMP is executed, transmit this message & data from Edit
Buffer.
20(8) RECEIVE DATA FORMAT ERROR
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,24,
| ProductID (electribe sampler)
| 0010 0110 (26) | DATA FORMAT ERROR
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
When found an error in the received message (e.g. data length), transmits
this message.
21(9) DATA LOAD COMPLETED (ACK)
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,24,
| ProductID (electribe sampler)
| 0010 0011 (23) | DATA LOAD COMPLETED
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
When DATA LOAD,PROCESSING have been completed, transmits this message.
22(10) DATA LOAD ERROR (NAK)
+----------------+--------------------------------------------------+
|
Byte
|
+----------------+--------------------------------------------------+
| F0,42,3g,
| EXCLUSIVE HEADER
| 00,01,24,
| ProductID (electribe sampler)
| 0010 0100 (24) | DATA LOAD ERROR
| 1111 0111 (F7) | EOX
+----------------+--------------------------------------------------+
Korg Electribe 2/Sampler - Aide-mémoire
Utilisation avancée - 2.3 Guide des paramètres du modèle « electribe Sampler»
Description
:
Description
Description
Description
(TABLE 7, NOTE 1,3) |
Mars 2019
|
R/T
|
|
|
51H
|
|
|
T
|
|
|
26H
|
|
T
|
|
|
23H
|
|
T
|
|
|
24H
|
|
105/166

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Electribe sampler

Table des Matières