Lowering the temperature during unoccupied periods
Unoccupied periods*
20 minutes
40 minutes
1 hour
72 hours
* Unchangeable factory settings
Note: when presence is detected in the room, the device automatically
returns to the initial mode.
Remarks:
By default, when the sensor is enabled and detects movement in the
room, the display lights up for a few seconds then switches off. To
change the backlight
see page
• Operation
Setting
temperature
19°C
18°C
17,5°C
17°C
7°C
19°C
18°C
17,5°C
-1°C
-1,5°C
20min.
40min.
Unoccupancy detected
• Divisions of the detection zone
Top view
Inactive area
Side view
Value of lowering
setting temperature*
Comfort -1°C
Comfort -1,5°C
Comfort -2°C
Frost protection
12, backlight setting.
17°C
-2°C
60min.
72hr
Occupancy detected
Detection zone, for a tempera-
ture of 19°C.
The detection zone is divided
into active and inactive areas.
A person that crosses the area
will be detected by the infrared
Active area
sensor.
INFORMATION ABOUT REMOTE
CONTROL BY PILOT WIRE
• Overview
Your device can be controlled by a central control unit through a pilot
wire, in which case the different operating modes will be remotely en-
abled by the programmer.
You can only control the device by pilot wire in the Auto mode. In the
other modes, the orders transmitted by the pilot wire will not be exe-
cuted.
In general, a pilot wire control system makes it possible to impose exter-
nally a lowering of the temperature setpoint, combined with the inter-
nal programming and the occupancy detection.
If several lowering requests appear simultaneously, priority is given to
the lowest temperature setpoint, thus maximizing savings
mation on priorities for different modes on page
When a signal is sent from the pilot wire, the self learning optimization
function is suspended.
Below the different views of the display for each order sent by pilot wire:
auto
auto
7°C
3
Pilot wire = Comfort
Time
mode
mode
auto
auto
3
Pilot wire = Eco - 2
mode
mode
Comfort - 2°C
auto
auto
Pilot wire = Boost
mode
mode
• Load shedding
In case of over consumption, an energy power manager or a disconnec-
tor doesn't trigger a trip of the general circuit-breaker (example: simul-
taneous operating of your various household appliances and others).
This allows you to reduce the energy power subscribed and therefore
optimize your subscription with your energy provider.
IMHOTEP creation controllers are designed to operate with pilot wire
load shedding systems.
Orders sent by the pilot wire are executed by the device's electronic
controller which will apply the setpoint corresponding to the order sent.
The "Stop" order corresponds to the load shedding. When this order is
received, the device switches to "standby" and then returns to the initial
operating mode.
Important: Do not use load shedding by a power fail. Unlike
pilot shedding, this type of shedding results in a series of sud-
den and frequent power cuts, which cause premature wear of
the device or even deterioration not covered by the manufac-
turer's warranty.
Exemption to an order coming from a pilot wire
external programmer
This feature allows you to modify temporarily the setting temperature
until the next order sent by the central control unit or the transition to
00:00.
prog
prog
auto
auto
prog
prog
boost
3
Pilot wire = Eco
OK
OK
OK
OK
mode
mode
Comfort - 3,5°C
prog
prog
auto
auto
prog
prog
boost
3
Pilot wire = Frost
OK
OK
OK
OK
mode
mode
protection
prog
prog
boost
OK
OK
EN
(see infor-
11).
auto
auto
prog
prog
boost
boost
3
Pilot wire = Eco - 1
OK
OK
mode
mode
Comfort - 1°C
auto
auto
prog
prog
boost
boost
Pilot wire = Stop
OK
OK
mode
mode
(Standby mode)
9