AMBIENT TEMPERATURE SENSOR
ADJUSTEMENT
Overview
Important: This operation is reserved for professional installers only;
any wrong changes would result in control anomalies.
In which case if the temperature measured (measured by reliable ther-
mometer) is different by at least 1°C or 2°C compared to the setting
temperature of the radiator.
The calibration adjusts the temperature measured by the ambient tem-
perature sensor to compensate for a deviation from + 5°C to - 5°C by
intervals of 0.1°C.

Ambient temperature sensor adjustement

1- If the room temperature difference is negative, example :
Setting temperature (what you want) = 20°C.
Ambient temperature (what you read on a reliable thermometer) =
18°C.
Difference measured = -2°C.
Important:
Before carrying out the calibration it is recommended to
wait for 4h after the setting temperature modification to insure that
the ambient temperature is stabilized.
To correct, then proceed as follows :
Sensor temperature = 24°C
(The measured temperature may be different due to the location of the
thermostat in the room).
auto
auto
mode
mode
Decrease the temperature measured by the ambient temperature sen-
sor by 2°C by pressing
.
In our example the measured temperature by the sensor goes
from 24°C to 22°C.
auto
auto
mode
mode
2- If the room temperature difference is positive, example :
Setting temperature (what you want) = 19°C.
Ambient temperature (what you read on a reliable thermometer) =
21°C.
Difference measured = +2 °C.
To correct, then proceed as follows :
Sensor temperature= 21°C.
(The measured temperature may be different due to the location of the
thermostat in the room).
auto
auto
mode
mode
prog
prog
boost
OK
OK
prog
prog
boost
OK
OK
prog
prog
boost
OK
OK
Increase the temperature measured by the ambient temperature sensor
by 2°C by pressing
.
In our example the measured temperature by the sensor goes
from 21°C to 23°C.
auto
auto
mode
mode
To validate, save the new value and exit the mode, press
Expert settings, press
3 times.
The reset to zero of the sensor calibration
To put the value of the correction to "0", do the following :
1- When the temperature measured by the sensor appears, press
for at least 3 seconds.
auto
auto
mode
mode
2- To save and move automatically to the next setting press
To exit the Expert settings, press
Important:
These changes should be performed by a qualified
staff, it should be performed in production or on site during the
first installation.

SETTING THE POWER

To have a controller adapted to the towel rails and estimate the energy
consumed, it is essantial to set the power of the device.
1- Pre set value: 500W. Select a value between 300W and 1500W by
pressing
or
.
auto
auto
mode
mode
2- To save and move automatically to the next setting press
auto
auto
mode
mode
3- To save the Expert settings, press
EN
prog
prog
boost
OK
OK