Variateurs c.a. PowerFlex Série 750
f3
ND Rating
600V, 60 Hz Input
Code
Amps
Hp
B, J,
L, T
1P7
1.7
1
2P7
2.7
2
3P9
3.9
3
6P1
6.1
5
9P0
9
7.5
011
11
10
012
12
10
017
17
15
018
18
15
022
22
20
023
23
20
024
24
20
027
27
25
028
28
25
–
032
32
30
033
33
30
041
41
40
042
42
40
052
52
50
053
53
50
063
63
60
077
77
75
099
99
100
125
125
125
144
144
150
192
192
200
242
242
250
289
289
300
295
295
300
355
355
350
395
395
400
8
435
435
450
460
460
500
510
510
500
595
595
600
630
630
700
760
760
800
9
825
825
900
900
900
950
980
980
1000
1K1
1110
1100
10
1K4
1430
1400
Δ
Available as a drive with options (21G).
10
Description des références (suite)
Frame
Enclosure Code
Code
K, P,
F
G
N
R
W, Y
012
015
020
3
3
3
023
030
034
–
6
6
046
3
3
3
050
–
6
6
061
3
3
3
082
098
–
6
6
119
4
4
4
142
–
6
6
171
–
4
4
4
212
–
6
6
263
5
5
5
265
–
6
6
330
5
–
5
370
415
460
–
500
6
6
590
650
710
765
7
7
795
960
1K0
1K4
Δ
–
Available as a drive with options (21G).
Δ
8
–
–
Code
A
Δ
9
J
♦
480V drives must select code "A." Jumpers are included for field
reconfiguration as desired.
10
Δ
Publication Rockwell Automation 750-IN001M-FR-P – Août 2013
f4
ND Rating
690V, 50 Hz Input (not UL listed)
Frame
Enclosure Code
Amps
kW
B, J,
K, P,
F
G
N
L, T
W, Y
12
7.5
15
11
20
15
23
18.5
30
22
34
30
46
37
6
6
50
45
–
–
61
55
82
75
98
90
119
110
142
132
171
160
212
200
7
7
–
263
250
265
250
330
315
370
355
Δ
8
8
415
400
460
450
500
500
590
560
–
–
650
630
710
710
Δ
9
9
765
750
795
800
960
900
1040
1000
10
10
Δ
1400
1400
g
♦
Filtering and CM Cap Configuration
Filtering
Default CM Cap Connection
Yes
Jumper Removed
Yes
Jumper Installed
h
Dynamic Braking
♠
Code
Internal Resistor
A
No
N
No
♠
Frames 1...2 only.
R
∇
Standard on Frames 1...5, optional on 6...7.
&
Not available on Frames 8...10, specify Code "N."
i
Door Mounted HIM (Frames 8...10)
Code
Operator Interface
0
No Door Mounted HIM
2
Enhanced LCD, Full Numeric, IP20
4
Enhanced LCD, Full Numeric, IP66 NEMA Type 4X/12
PowerFlex 755 w/Options (21G) - Required Selections
Code
Option
LD
Light Duty
–
ND
Normal Duty
HD
Heavy Duty
Input Thermal Magnetic
P3
Circuit Breaker
Input Non-Fused Molded
P5
Case Disconnect Switch
P14
Wiring Only Bay
Only one option of this type may be selected.
PowerFlex 755 w/Options (21G) - Additional Selections
Code
Option
P11
Input Contactor
P12
Output Contactor
L1
3% Input Reactor
L2
3% Output Reactor
L3
5% Input Reactor
L4
5% Output Reactor
P20
1200 Amp Bus
P22
2000 Amp Bus
P24
3000 Amp Bus
UPS Control Bus, DC Input
P30
w/Precharge only
Auxiliary Transformer
X1
(500VA available), IP20
Cabinet Only
Only one option of this type may be selected.
§
Contactor options are not available for systems with MCC power bus.
&
∇
Internal Transistor
Yes
No
Frames
Type
System Overload
8...10
Duty Cycle
8...10
Power
Disconnect
8 Only
8...10
Wiring Only Bay
Frames
Type
8 Only
Contactors
§
8...9
Reactors
8 Only
MCC Power Bus
8...10
Capacity
8...10
UPS Control Bus
8 Only
Auxiliary Power