As Found" Measuring Results - SKF TKSA 11 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33

3.10 "As found" measuring results

The parallel "offset" and angular misalignment results for the
vertical and horizontal axes or planes are shown in a combined
view. Graphics show the position of the machine from a side
and a top view.
The values are compared with the selected tolerances and the
symbols in right indicate if the values are within tolerance.
Within tolerance:
Out of tolerance:
X
a.
Remeasure
If required, select "Remeasure" to cancel the results and make a new set of measurements.
b.
Done
Accept the results and go to the main menu. A report is created.
Note:
It is possible to resume the alignment after "Done" has been selected.
c.
Align
Perform vertical and horizontal correction.
The green "Align" button indicates some values are out of tolerance and correction
is needed.