! Shortly press the button [2]. The siren's readiness for operation is
confirmed by a beep.
! To deactivate the siren if necessary, shortly press the button [2]. After
that, press the button again, and hold it for 6 seconds, until the
switching off is confirmed by a beep.
The delay can be set by pressing the button [2]. The setting will be confirmed
by a beep.
Delay
Press button
15 seconds
2x
30 seconds
3x
no delay
4x
factory default: 30 seconds
9.2 PIR-detector 3000P/3000P2
The detector in the set is already enrolled to the siren.
! Open the housing by pressing the clip [19] with a small screwdriver.
! Insert two suitable alkaline 1.5 V, AA batteries into the battery
compartment [28], observing correct polarity.
! Close the housing fully so that it clicks to. After inserting the batteries the
detector enters a 16 seconds stabilising period indicated by flashing of
the LED [14] every second. Afterwards the detector is in operating mode.
3 minutes after the batteries have been inserted, the LED flashes and the
detector is in operating mode. To test the detector enter the test mode by
pressing the test button [17]. You now have 3 minutes time to test the
coverage of the sensor: Hold the detector in the proposed position and then
ask somebody to walk across the monitored area. A detection will be
indicated by the LED [14]. After up to10 seconds deactivation the sensor is
reactivated and is ready for another detection.
After 3 minutes in Test mode the deactivation period is increased to 3-5
minutes, to save battery power (operating mode) that means that the PIR
only sends a signal to the siren after it has not registered movement for a
period of 3 to 5 minutes.
! Set the LED/ZONE jumpers [29/30] to the desired setting (see chapter
10 - note: in this case all components must be enrolled again).
! Secure the housing with screw [21] into screwhole [20] using a small
screwdriver.
9.3 Door/window contact 3000M
The detector in the set is already enrolled to the siren.
! Slide the battery compartment lid downwards and lift it from the sensor
[31].
! Set the ZONE jumper [36] to the desired setting (see Chapter 10 - note
in this case all components must be enrolled again).
! Insert a suitable alkaline 1.5 V, AA battery into the battery compartment
[37], observing correct polarity.
! Close the housing fully so that it clicks to. The detector is now in
operating mode.
! Test the detector from the proposed position, a detection will be
indicated by the LED [32].
9.4 Remote control 3000R
The remote control in the set is already enrolled to the siren and is
operational since the battery is already installed.
10. Setting the detectors
The detectors can be set according to the position of jumpers which connect
two pins together.
Remove batteries before changing the jumper positions.
After the position of a jumper in any enrolled detector has been
changed it is necessary to reset the siren and reenroll all
components (see chapter 20 and 19).
jumper connected
{
jumper not connected
10.1 ZONE jumper [30/36](3000P , 3000M)
D0 D1 D2 D3
setting
{
{
Immediate
{
{
alarm
{
{
delayed alarm delayed alarm in full and part
{
{
{
{
Home mode
{
{
{
24 h
{
* If the delay in the siren is set for no delay a delayed detector will give an
immediate alarm.
Factory default: delayed alarm
All functions are described in chapter 7.
10.2 LED jumper [29] (3000P)
OFF
ON
{
LED active (LED indicates a detection and low
battery)
{
LED deactivated
factory default: LED on
11. Installation
11.1 PIR-detector 3000P/3000P2
! Mark the fixing positions on the wall through the fixing holes [23] of the
bracket [22].
! Drill two holes and insert the wall plugs [27].
! Fix the bracket with screws [26] to the wall.
! Press the ball joint [25] into the bracket [24].
reaction
immediate alarm in full and
part arm
arm*
immediate alarm by full arm,
no alarm in part arm
always alarm
29