ERROR CODES

Error Code
General Functions
TEMP SENSOR OPEN ERROR
It occurs due to a defective sensor, misplaced wires, a defective PCB
and when A/D value that MICOM senses falls under 10.
TEMP SENSOR SHORT ERROR
It occurs due to a defective sensor, misplaced wires, a defective PCB
and when A/D value that MICOM senses rises over 252.
TEMP SENSOR TARGET TEMP
It occurs when the preheating is not completed and the temperature of
cavity inside is under 120 °C for 30 minutes.
ABNORMAL TEMP SENSING ERROR
It occurs when the tmperature of cavity inside is over 250 °C for 10
minutes.
MICROWAVE ABNORMAL TEMP SENSING ERROR
It occurs when the tmperature of cavity inside is over 210 °C in the
Microwave Mode.
KEY SHORT ERROR
This error occurs when a button is pressed and held for over 60
seconds.
It may occur when water soaks through the inside of the control panel
or dust particles are stuck to TOUCH PAD.
NAK SIGNAL ERROR
Nak signal occurs if initial power-up for more than 10 seconds.
COMMUNICATION ERROR
It occurs when not communicating between main and sub PCB for more
than 10 seconds.
EEPROM OPEN ERROR
It occurs when EEPROM communication is error during initial power
setting.
EEPROM READ & WRITE ERROR
Eeprom use does not occur.
If any of these errors occur, please contact ATAG Customer Service.