TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
FUEL
- Net caloriÞc value
- Absolute density
- Max delivery
- Pressure at maximunm delivery
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
MOTOR CAPACITOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
ELECTROMAGNETIC COMPATIBILITY
NOISE LEVELS
(3)
APPROVAL
APPROVAL
(1) Reference conditions: Ambient temperature 20 ° C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 8)(A)p.8, with zero pressure in the combustion chambre an maximum burner output.
(2) Sound pressure measured in manufacturerÕs combustion laboratory, with burner operating on test boiler and at maximum rated output.
ACCESSORIES
(optional):
¥
KIT FOR LPG OPERATION : the kit allows the 30 - 40 BLU burners to operate on LPG.
BURNER
OUTPUT
CODE
¥
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valve, pressure governor and Þlter): see page 18.
COUNTRY
IT - AT - GR - DK - FI - SE
ES - GB - IE - PT
NL
FR
DE
BE
LU
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
2nd stage
min. 1st stage
(2)
kW
CATEGORY
II
II
II
2ELL3B /P
I
2E(R)B,
II
RS 30 BLU
831 T1
kW
210 - 350
181 - 300
Mcal/h
kW
130
112
Mcal/h
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
3
kWh/Nm
10
3
8,6
Mcal/Nm
3
0,71
kg/Nm
3
35
Nm
/h
mbar
13,3
- Intermittent (min. 1 stop in 24 hours)
- Two - stage (high and low ßame) and single-stage (all - nothing)
Boilers: water, steam, diathermic oil
° C
0 - 40
° C max
60
V
~ 50 Hz 230 V (+/- 10%)
W
420
V
220 - 240
A
2,9
m F / V
12,5/450
V1 - V2
230 V - 1x 8 kV
I1 - I2
1 A - 20 mA
W max
600
IP 44
90/396 - 89/336 - 73/23 - 92/42
dBA
70
CE
0063AR4682
BUWAL Nr
196020
RS 30 BLU
130 ¸ 350
3010148
2H3B / P
II
2H3P
2L3B / P
II
2Er 3P
I
3P
2E3B /P
6
RS 40 BLU
827 T1
325 - 465
280 - 400
175
150
G25
G20
8,6
10
7,4
8,6
0,78
0,71
40
46
19,7
13,8
420
220 - 240
2,9
70
RS 40 BLU
175 ¸ 465
3010149
GB
G25
8,6
7,4
0,78
54
20,4