Service And Repairs - Aventics ECD-IV Notice D'instruction

Éjecteur compact
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
AVENTICS | ECD-IV | R412025990–BAL–001–AC | English
System menu
A special menu is available for checking system data, such as the counters, software
version, item numbers and serial numbers. The operating structure is as follows:
X 10
>3 sec.
X 10
X 10
>2 sec.
Displaying data in the system menu
1. To display data in the system menu, simultaneously press and hold the buttons
and
> 3 s.
[-S-] appears during actuation.
2. To select the value you wish to display, press the button
3. Press the button
to confirm the value.
The value is displayed
4. To leave the system menu, press the button
Displaying the counters
This menu item displays the counters [cc1] (suction cycles) and [cc2] (number of
valve switches).
The last three decimal places for the total counter value are displayed. The decimal
point furthest to the right flashes. This corresponds to the block of three numbers
with the lowest value.
You can use the buttons
or
counter value. The decimal points indicate which block of three numbers from the
total counter value is shown in the display.
The total value of the counter is made up of 3 blocks of numbers:
Digits displayed
Number block
In this example, the total counter value is 48 618 593.
Displaying the software version
The software version provides information regarding the current software on the
internal controller.
Displaying the material number
The material number is also stored electronically in parallel to the label on the
ejector.
To begin with, the first two digits of the material number is displayed. Use the button
to display the remaining digits.
In total, the article number is made up of 4 blocks of numbers with 10 digits.
1
Number block
In the material number in the example above is R412010614.
To leave the system menu, press the button
Counter 1
+
3
+
3
X 10
Counter 2
+
3
+
3
X 10
Software version
Material number
Internal index
+
3
+
3
X 10
or
>2 s.
to display the other decimal places in the total
6
3
10
10
2
3
>2 s.
8

Service and Repairs

External contamination
Damage and disruptions due to penetrating fluids or contact with aggressive
media
Penetrating fluids and use of solvents and aggressive cleaning agents can lead to
damage and disruptions.
In this case, reliable ejector function can no longer be guaranteed.
O Only clean the ejector with a damp, lint-free cloth.
O Only use water and, if necessary, a mild detergent for cleaning.
O Make sure that the silencer and the controller are not soaked in fluid.
O Do not use a high-pressure cleaner.
Silencer
Damage due to excessive force
.
Exerting excessive force when tightening the mounting screws can lead to
damage to the housing.
O Observe the maximum torque of 0.5 Nm when tightening the mounting screws
on the silencer module.
We recommend that you also replace the damping plate when exchanging
the silencer insert.
The open silencer can become soiled if exposed to very heavy contamination by dust,
oil, etc. and thus reduce the suction capacity. It should be replaced in this case. Due
to the capillary effect of the porous material, cleaning is not recommended.
Press-fit screens
0
10
Damage to ejector system due to missing press-fit screen
Fluids and foreign objects could penetrate and destroy the ejector.
O Do not operate the ejector system without press-fit screens.
Press-fit screens are installed in the vacuum and compressed air connections.
Over time, dust, chips and other solid matter can deposit in these screens.
If the ejector system performance noticeably drops, the screens can easily be
replaced.
Spare and wearing parts
Designation
Silencer insert
Screen
4
Damping plate
9
Troubleshooting
Error
The ejector's error messages are shown on the display.
Symbol
NOTICE
NOTICE
NOTICE
Error code
Electronics error - EEPROM
Electronics error – Internal communication
Zero-point adjustment for the vacuum sensor outside of
±3% FS
Supply voltage too low
Short circuit at output 2
Supply voltage too high
17
Material number
R412026154
R412026155
R412026156

Publicité