4. MAINTENANCE
4.1
Precautions
Before servicing pump or plant verify that all electric connections (power and control) have been disconnected
from mains and are no more fed.
Depressurize completely pump and pipes and drain the section in which maintenance is required
Always work wearing the required safety protections.
Don't pour in the ambient polluting substances such as pumped chemicals, hydraulic liquid, lubricating oil a.s.o.
Before servicing pump or plant read carefully the technical specification of the handled fluids with particular re-
spect to the actions that must be done in case of accidental contact with a dangerous fluid.
4.2
Mechanism
Pumps are generally supplied complete with the first oil filling; replace oil after 1500 operation hours and after-
wards every 4000 hour.
However replace oil every year .
Check weekly the oil level and, when required, restore the correct level using the same oil; check also for possible
leakages through the lip seal on the piston rod and if necessary replace the lip seal.
ATTENTION!
Please use only oil with these features:
4.3
Pumphead
Don't let the pump running without process liquid.
As minimum every six months, dismount the pumphead as follows:
Disconnect suction and discharge pipes
Drain process liquid rom pump head and pipes
unscrew bolts fixing the pumphead to mechanism
dismount suction and discharge valves
and carry out he following operations:
wash thoroughly the suction and discharge valves and verify whether any part is worn or scratched; replace them
if required
replace plunger packing in case it is worn; grease new seals before assembling
check the plunger sliding surface where seals operate; the surface should be without scoring or scratches; when
damaged replace the plunger
4.4 Recommended spares
In order to face normal service problems and to avoid possible waste of time, we suggest to keep in stock a small
supply of the following spares:
One plunger
Two sets of plunger packing
One suction valve complete
One discharge valve complete
When ordering spares, please indicate always the model and the serial number of the pump
SPR0136001
ISO VISCOSITY GRADE 320
Rev. 2.4
EN
7