4. Maintenance
4.1 Instructions for oil-filling
Attention
The lubrication grease is filled as shipped from our factory.
Replace oil after 1500 operation hours and afterwards every 4000 hour
4.2 Disassembly and installation of pump head
1) Disassembly
2) Assembly
Attentions
1. Before disassembling the diaphragm, please position the knob at " Zero" flow rate
2. The tightening torque for diaphragm is 4 N/m
3. After installation of diaphragm, the knob must be positioned at " 100%" flow rate and
then install the pump head
SPR0136037
Internal bearing and
adjustment rod shall
be lubricated
Rev. 1.5
10