9. Faults

Warning:
-
Disconnect the power supply before carrying out work on the unit.
-
Work must only be carried out on the equipment by an electrical engineer with the
relevant training and qualifications.
Probleem
LED is off
LED do not light
up orange, keep
flashing green
LED light up red
LED is flashing
red, slow, 1 Hz
LED is flashing
red, fast, 5 Hz
IQComGeneratorConverter_UM_9752103110_NL_D_GB_F_V1_0
Mogelijke oorzaak
No supply voltage
Faulty wiring
Cable break in the M12
connection
cable/connector
High voltage set too low
(<1kV)
IQ Com is not set to "Run"
mode
"Remote On/Off" signal is
not active
CM5 parameters are not
correct
Output voltage set too
high, arcing at the
charging bar/electrode
Short circuit between
charging bar / electrode or
HV cable and earth
Eeprom read error warning Check the parameter settings and then
Eeprom read error alarm
Supply voltage too low
CM5 generator not
connected or powered
down
"HV OK" output
overloaded
Output current peak too
low or too high
Charging pulse too long
No communication
between the IQ Com and
the IQ Easy manager
Oplossing
Switch on 24 V DC supply voltage
(Switch on Manager IQ Easy)
Locate fault and remedy, see 5.3
Replace M12 cable/connector
Increase output voltage by increasing
setpoint (6.2)
Set the IQ Com to "Run" mode (6.2)
Set the "Remote On/Off" signal to active
or set the IQ Com to "Continuous mode"
(6.2)
Change CM5 parameters (6.1)
Reduce output voltage by reducing
setpoint or increasing distance to earth
Locate short circuit and eliminate
restart the IQ Com
The IQ Com is defective, ask a RMA and
send it back to Simco
(Chapter 10)
Check the supply voltage (IQ Easy
manager)
Connect the CM5 generator to the IQ
Com and make sure it is powered on
Eliminate overload (24 V DC > 50 mA)
Set the output current peak warnings /
alarms to the correct value (6.2)
Set the time for the charging pulse and
the charging pulse warning to the correct
value (6.2)
Check the wiring between the IQ Com
and the IQ Easy manager
Restart the IQ Easy manager