8. Faults

Table 1: Faults
Signaling
Problem
[On] LED on
No/poor ionisation
High voltage on emit-
[Fault] LED off
ters.
Bar operating
OK active
(external)
[On] LED off
No high voltage on
emitters.
[Fault] LED off
Bar operating
OK not active
(external)
[On] LED on
No high voltage on
[Fault] LED on
emitters
or flashes
Bar operating
OK not active
(external)
[Fault] LED
None
and [ON] LED
flash on and
off

9. Repair

Warning:
-
When working on the equipment, always disconnect the power supply to the
equipment.
-
Repairs must be made by a skilled electrical engineer.
When opening the equipment, parts under hazardous voltage
-
can be touched.
SIMCO (Nederland) B.V. recommends that you return the ThunderION anti-static bar if repairs
are required.
To request an RMA form for this purpose, please send an e-mail to service@simco-ion.nl.
Pack the equipment well and clearly state the reason for return.

10. Disposal

Comply with locally applicable environmental and other regulations when disposing of
the product.
ThunderION_UM_9752160010_NL_D_GB_F_V2_2
Cause
Bar is fouled.
Emitters are damaged.
Emitters are covered.
Remote function set to Off.
No supply voltage
present.
Bar faulty.
Bar placed too close to con-
ductive parts
Bar is extremely fouled.
Bar faulty.
Signalling of the pulse fre-
quency after the 24 V DC has
been switched on or the pulse
frequency switch has been
turned (Section 6.2)
Remedy
Clean bar.
Replace emitters.
Remove the cover.
Set Remote to On.
Restore supply voltage.
Return bar
Move bar.
Clean bar.
Return bar.
After the pulse frequen-
cy has been displayed,
the [On] LED turns on
again.