Télécharger Imprimer la page

Information/Settings Tab; Graphics Tab; Actionlog Tab - ITW Simco-Ion IQ Com Notice D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

Figure 14, Graphics tab.

7.2.1. Information/settings tab

With the
buttons you can scroll through the various pages. The following data on the
operation can be found here:
-
Output voltage (kV): Indicates the current value of the high voltage on the HV output
-
Output current (mA): Indicates the current value of the current on the HV output
-
Output voltage peak (kV): Indicates the peak value of the high voltage on the HV output
-
Output current peak (mA): Indicates the peak value of the current on the HV output
-
Last warning: date and time of the last occurred Warning
-
Last alarm: date and time of the last occurred Alarm
-
Arcs per minute: displays the number of arcing per minute, see chapter 6.2.9
If a Sensor IQ Easy is connected to the IQ Com, the display will also show:
-
Web voltage (kV): the current average charge measured by the active segments of the
sensor bar, see chapter 6.2.7
-
Web voltage peak (kV): the maximum charge measured by the active segments of the
sensor bar, see chapter 6.2.7

7.2.2. Graphics tab

The Graphics tab graphically shows the operation as function of the time.
-
Blue : the output voltage at the HV output (kV).
-
Yellow : the output current an the HV output (mA).
If the screen is clicked, the screen will "freeze", and "On hold" will show on the display. Clicking
the screen again will display the current value.

7.2.3. ActionLog tab

In the ActionLog tab, the changing status of the IQ Com is logged step-by-step. This is indicated
including the date and time the status change has occurred. The main messages are:
-
HV OK: the generator is turned on and is functioning properly
-
HV NOT OK: the generator is turned off or the high voltage doesn't function properly
-
REMOTE ON:
-
REMOTE OFF:
In the Maintenance tab (Figure 17) the ActionLog tab can be emptied.
IQComGeneratorConverter_UM_9752103110_NL_D_GB_F_V1_0
Figure 15, Action log tab.
GB
49

Publicité

loading

Ce manuel est également adapté pour:

Simco-ion iq easy