VC (Voltage Control) mode operation:
Figure 10, operation VC-mode
CC (Current Control) mode operation:
IQComGeneratorConverter_UM_9752103110_NL_D_GB_F_V1_0
If the IQ Com is set to VC mode, the desired
output voltage must be set with the parameter
"Setpoint voltage." The generator will now
consistently maintain the set output voltage and
adjust it depending on the load with a larger or
smaller current. The charging current depends on
the load of the generator and the possible fouling
of the charging bar/electrode. The maximum
output current can be set using the parameter
"Output current limit". Only if the output current
reaches the value of the "Output current Limit"
parameter, will the output voltage drop.
If the IQ Com is set to CC mode, the desired
output current must be set with the parameter
"Setpoint current." The generator will now
consistently maintain the set output current and
adjust it depending on the load with a larger or
smaller voltage. The maximum output voltage can
be set using the parameter "Output voltage limit".
Only if the output voltage reaches the value of the
"Output voltage limit" parameter, will the output
current drop.
For correct operation change also the Control
parameter on the CM5 generator to CC (Control
mode 2/4: CC, see chapter 6.1)