8.3.10 data (data) - upload and download
data (data) - upload and download
of parameters between the operating
unit and the basic device
This function is used for data transfer from one operating unit to several ba-
sic devices. After connecting the operating unit, the stored parameters can
be transmitted to the basic device.
nOTe!
This function is only available for the cable head version.
upld (upload)
When upload is selected the parameters of the basic device are transferred
to the operating unit. That means, that first the memory of the operating unit
is cleared and then filled with all relevant data of the basic device. After that
the operating unit displays "rdY" (ready). If the data transfer failed "Err" (er-
ror) is displayed.
dnld (download)
When download is selected the parameters stored in the operating unit are
transferred to the basic device. This is only possible, if the version of the
data is the same as in the basic device (e. g. data transfer between a
200 - 1000 mA version and a 500 - 2000 mA version is not possible).
After that the operating unit displays "rdY". If the data transfer failed "Err" is
displayed.
8605 - 9