Electrical Installation; Electrical Installation - Impulse Min 24V - Min 1V5 Model - Bodet Time Profil 750 Manuel D'installation Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.2.2 Electrical installation

There are two different clock versions: IMPULSE MIN 24V, MIN 1V5 or AFNOR.
Refer to the product label to determine which version you have.
The lighting (if option chosen) is always powered via a mains power supply.

2.2.2.1 Electrical installation - IMPULSE MIN 24V - MIN 1V5 model

- With lighting option: feed the mains cable through the bracket arm then connect this cable to the
1
terminal block
in the N-L-
- Feed the synchronisation power cable through the bracket arm then
connect the cable to the terminal block
Take care to observe the correct wiring. (see opposite)
- Attach these cables to the central bracket with cable retainers
- Clean the seal and then apply silicone oil on it,
- Realign the disassembled clock face then reconnect the cable
the movement
3
on the disassembled clock face,
- Limit the length of the cable by passing it through the cable clip in order to avoid shading in the
case of the lighting option (contact of the cable with the dial once the clock is closed),
- Close the clock by placing the disassembled clock face back in its original position,
- Tighten the four cover screws (1,2 Nm) on the newly remounted clock face,
- Replace and tighten the air inlet screw (15 Nm) on the underside of the bracket arm.
26
terminals reserved for lighting
1
in terminals 1 and 2 SYNC,
1
2
,
,
white
brown
3
between the terminal block and
2
EN
white
brown
Impulse network

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Profil 760

Table des Matières