2.1.2 Electrical installation
There are two different clock versions: IMPULSE MIN 24V, MIN 1V5 or AFNOR.
Refer to the product label to determine which version you have.
The lighting (if option chosen) is always powered via a mains power supply.
2.1.2.1 Electrical installation - IMPULSE MIN 24V - MIN 1V5 model
- With lighting option: feed the mains cable through the left-hand cable gland then connect this
cable to the terminal block
- Feed the synchronisation cable through the small central cable gland then connect this cable to
1
the terminal block
in terminals 1 and 2 SYNC,
Take care to observe the correct wiring. (see opposite)
- Attach these cables to the fixing plate with cable retainers
- Clean the seal and then apply silicone oil on it,
- Realign the front face to reconnect the synchronisation cable
the movement
on the front face,
3
- Limit the length of the cable by passing it through the cable clip
the case of the lighting option (contact of the cable with the dial once the clock is closed),
- Close the clock by placing the front face back in its original position,
- Tighten the four cover screws (1,2 Nm),
- Replace and tighten the air inlet screw (15 Nm) on the underside of the clock.
in the N-L-
terminals reserved for lighting
1
1
1
,
white
brown
4
2
3
between the terminal block and
2
in order to avoid shading in
4
EN
,
white
brown
Impulse network
23