11
Technical data
1
Deflector hood Z66
The deflector hood Z66, which is made of plexiglas, enables the mist emerging
from the unit to be deflected at an angle of inclination of approximately 30°.
For this purpose the deflector hood is mounted on the top opening of the unit
and the latter is then used without the standard insertion collar. If the output
is too high, the deflector hood can also be mounted on the insertion-collar,
but the propeller may then brush the hood slightly owing to the reduction in
diameter. In this case the propeller should be shortened a little at each end
with the aid of a sharp pair of scissors. To avoid spurts, make sure that the
propeller is right on top of the shaft end and rotates in the bottom portion of
the deflector hood.
Use of the deflector hood is recommended in those cases in which the
Condair unit is mounted on a wall or a pillar so as to prevent the wall behind
the unit being wetted by the mist. A further application for the deflector hood
is in cases where for some reason or other the mist has to be diffused in a
certain direction. Use of the deflector hood will reduce the output of the unit
by about 10 - 20 per cent.
Control basin 2
For the continuous water supply. It is provided with a sediment drain screw
so that it can be cleaned without being dismantled. The control basin can
be used wherever a water drain is available or can be easily installed (see
explosion diagram).
Humidification capacity:
For rooms:
Air circulation:
Power consumption:
Dimensions (dia. x height):
Dry weight:
Voltages:
up to 3 litres/h
up to 500 m
3
280 m
/h
3
65 W
420 x 350 mm
7 kg
110/230/240V 50Hz
110/230V 60Hz