GB
IRL
Avoid ignition sources in the environment if you spray combustible liquids.
Do not leave the device in the sun. Make certain the device is not heated beyond
the maximum operating temperature. (→ Table 1). Protect the device from frost and
ammonia.
Never blow through the nozzles or valves with your mouth.
Use only MESTO spare and accessory parts.
We cannot assume any liability resulting from the use of third-party parts.
Wear suitable protective equipment when working with hazardous substances.
When pumping, always observe the pressure gage to ensure the maximum
spraying pressure is not exceeded (→ Table 1 below).
After use and before maintenance work, depressurize the spray line.
Scope of delivery
Backpack spraying device with spray line [1], spray lance [2], carrying strap [3], Instructions
for Use [4], seal set [5]. (Figs. 1a and 1 b)
You will find the illustrations referred to above in the front fold-out pages 3 – 5 of these
Instructions for Use.
Technical data
Type of device
Max. filling amount
Max. spraying pressure
Max. operating temp-
erature
Weight when empty
Material of tank
Where device is carried
Technical residual
quantity
Max. volume flow
Table 1
Assembly
1. Attach the carrying strap [3] to the tank. (Figs. 2a and 2b)
2. Screw the spray lance [2] onto the shut-off valve [6] (Fig. 3)
Checks
Visual inspection: Are the tank [1] with pressure vessel [14], as well as shut-off valve [6]
with spray line, pressure gage [11] and spray lance with nozzle [2] undamaged?
Pay special attention to the connections between the pressure vessel - spray line and
the spray line – shut-off valve and to the condition of the spray lance.
AUS
PRAKTIKUS 3537DG
15 l
4,3 kg
Polyethylene
USA
NZ
PERFEKT 3531G
17 l
6 bar
40 ° C
4,2 kg
Back
0,13 l
2 l/min at 2 bar
13
CDN
IND
STABILUS 3541G
18 l
5,0 kg
Stainless steel