ing.
• Tighten the T-handle hand-tight.
• Start the engine and let it run at half throt-
tle for 30 seconds.
Alternatively: Use the manual lever on the
fuel feed pump to allow manual bleeding.

Technical data

Type
Engine output
Maximum capa-
city
Imp. Gallon/hour
US Gallon/hour
(consumption +
return)
Number of filter
elements
Connections
Weight
Replacement fil-
ter
Filter
grade
standard
Certified
In determining the capacity of the various
types, it is assumed that there is always one
filter spare or on stand-by.
8
040306.01
75100VTME 79100VTME 83100VTME 87100VTME 91100VTME
up to 500
from 500 to
HP
1100 HP
from 368 to
to 368 kW
810 kW
1440 litres/
720 litres/hr
158
190
2
R 3/4
12,5 kg
20 kg
27.5 lbs
44 lbs
2020VTR = 30 micron red), 2020VTB = 10 micron (blue)
from 1100
to 2300 HP
from 810 to
1692 kW
2160 litres/
hr
hr
316
474
380
570
3
4
R 1
R 1 1/2
27,6 kg
60.8 lbs
30 micron
CE + ABYC + SOLAS (IMO)
To select the right type, we recommend
working on the basis of your engine power.
from 2300
from 3600
to 3600 HP
to 5000 HP
from 1692
from 2648
to 2648 kW
to 3678 kW
2880 litres/
3600 litres/
hr
632
790
760
950
5
R 1 1/2
R 1 1/2
35 kg
41 kg
77.1 lbs
90.4 lbs