Technical Data - Abus SG1660 Instructions D'installation

Sirène d'alarme
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Installation
1. Use the back of the flash and sounder case as a template for marking
the drill holes (2). Drill the holes for the fixing screws.
2. Pull the connector cable through the opening provided.
3. Fix the rear of the casing and the removal contact (7) to the wall.
4. Connect the cables to the terminal block (8) as described .
5. Replace the protective cover (9) and the casing cover (1) and tighten
the fixing screws.
Connections
Use only shielded and grounded cables.
Connect the flash and sounder cables to the corresponding control or
switching outputs of your alarm system. Check the total power
consumption. You can also incorporate the cover contact into the tamper
line of your alarm system.

Technical data

Voltage supply
Max. power consumption (without
flash)
Max. power consumption (with
flash)
Acoustic alarm
Protection type
Operating temperature
Dimensions (WxHxD)
Weight with flash / without flash
The manufacturer reserves the right to make technical modifications
without prior notice.
IMPORTANT: Make sure you connect the cables to the
right polarity, otherwise the flashlight may be irreparably
damaged.
10–15 V DC
340mA
750mA
110dB @ 1m
IP34
-25 to +55°C
190 x 310 x 120 mm
1,850g / 1,700g