Installation and maintenance instructions
panicLock AP4
29
5083118 / 03 / 2021
Contact pressure regulation and adjustment options
EN
Inside contact pressure adjustment auxiliary locking point
Contact pressure in single keeps or keep rails is regulated
by off-center adjustment plates on the inside. They can be
adjusted continuously with a 3 mm Allen wrench or with
a Torx T15 screwdriver (part no. 2953104) in the range
± 2 mm.
Contact pressure adjustment
TM-20-4-T single keep (timber 4 mm air gap)
Due to the ± sides of the TM-20-4-T hook keep, the contact
pressure can be varied by changing the mounting position
through 180°.
Contact pressure adjustment
TM-22-4-V single keep (timber 4 mm air gap)
Due to the ± sides of the TM-22-4-V hook keep, the contact
pressure can be varied by changing the mounting position
through 180°.
In addition, contact pressure in single keeps or keep
rails is regulated by off-center adjustment plates on the
outside. They can be adjusted continuously with a Torx T15
screwdriver (part no. 2953104) in the range ± 2 mm.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ D-98617 Meiningen ∙ T +49 3693 950- 0 ∙ www.winkhaus.de ∙ Subject to technical changes