4.3 Inserting the fi lter cartridge
Pull the fl ap of the protective cap
E
Note the next exchange date in the date fi eld on the fi lter cartridge
Insert the fi lter cartridge
F
Caution: The fi lter cartridge can only be inserted when the locking handle is open.
!
Make sure that the fi lter cartridge is positioned correctly.
Turn the locking handle
4.4 Commissioning
Open the water intake and switch on the terminal equipment's power supply.
G
Operate the fl ush valve
without bubbles. At least two empty fi lter cartridge volumes must be fl ushed (Chapter 9).
H
Note: When bleeding/fl ushing, catch water emerging from the fl ush hose
appropriate container.
Check system for any leaks.

5 Changing the Filter Cartridge

The PURITY C fi lter cartridge must be replaced once the stated capacity has been reached
(see Chapter 6), in accordance with manufacturer's specifi cations or no later than 12 months after
commissioning, whichever occurs fi rst.
Caution: When changing a fi lter, examine all remaining parts carefully! Faulty parts must be
!
replaced and contaminated parts should be cleaned! Read the operating and safety information
(Chapter 3) before changing the cartridge. After storage and transport below 0 °C, the product must
be stored in the open original packaging for at least 24 hours before it is commissioned at the stated
ambient temperatures (Chapter 9) for operation.
Note: When the locking handle is open, the water supply to the cartridge is interrupted and
short-circuit operation with direct water fl ow from the water inlet
possible (if necessary, close water intake and switch off power supply to the terminal equipment).
Open locking handle
Activate the fl ush valve
Remove exhausted fi lter cartridge
cartridge.
Note: The fi lter cartridge can be pivoted by 90° in the wall mounting bracket for easy removal.
Perform the steps described at 4.3 and 4.4.
6 By-Pass and Capacity Tables
The capacity tables for the PURITY C Quell ST and PURITY Finest C fi lter systems are provided on
pages 2–6.
The PURITY C AC and PURITY Fresh C fi lter systems have a fi lter capacity of 10,000 and 12,000 litres
respectively, regardless of the carbonate hardness and the by-pass set. All intake water is fi ltered.
Note: The stated capacities were tested and calculated based on standard application and machine
conditions. This information may vary according to external infl uencing factors (for example, fl uctuat-
ing crude water quality and/or machine type).
20
upwards and remove the protective cap.
7
in the fi lter head
6
until you feel it engage.
2
and fl ush the fi lter system until the fi ltered water runs clear and
8
.
2
and depressurise the system.
8
from the fi lter head
6
in a vertical position.
1
to the water outlet
4
,bearing in mind the weight of the
1
.
6
in an
9
is
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Purity c acPurity finest cPurity fresh cPurity c300 quell st

Table des Matières