Replacing The Filter Cartridge - Brita P 1000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
3.6
Step 6 (optional): Space-saving wall mount
to install the cartridge under the sink
(see fig. 9)
During assembly, note the installation dimensions, bending
!
radii of the hoses and dimensions of the accessories. The
system can be operated vertically and horizontally. When
using the wall mount, install vertically only!
1.
2.
3.
4.
(fig. 9)
A Attach the wall mount in place using the two matching screws
and use two wall plugs, if necessary, depending on the type of
wall.
B Engage the filter head (2) in the wall mount (1). Please use the
fixation holes (4).
10
ENGLISH
3.7
Step 7: Commissioning
Before use, make sure that you have followed all the steps
correctly and all the parts are fitted. Place a suitable container
under the cartridge to catch any leakages.
A Turn on the cold and hot water supplies and check the system
carefully for any leaks.
B Open the BRITA branded lever on your BRITA 3-Way Water
Filter Dispenser and rinse through until the filtered water runs
clear and without any bubbles (at least 2 litres).
4

Replacing the filter cartridge

The filter cartridge must be replaced when it runs out or at
l atest 6 months after commissioning, irrespective of the level of
e xhaustion of the filter system.
Read the Operating and Safety Information (chapter 9)
prior to exchange. After storage and transport below 0°C,
!
the product must be stored in the open original packaging
for at least 24 hours at the stated ambient temperatures
( c hapter 7) for operation.
The filter cartridge can be pivoted by 90° in the wall mount
for easy removal. When the locking handle is open, the
water supply to the cartridge is interrupted and by-passing
with direct water flow from the water inlet to the outlet is
possible.
Replacing the P 1000 (see fig. 8):
A Open the locking handle (3).
B Place a suitable container under the flush hose to catch the rinse
water. Activate the flush valve (5) and release pressure from the
system.
C Remove the exhausted filter cartridge (4) from the filter head (2) –
please be aware, the cartridge is firmly embedded so you can
give it a firm pull without worrying about breaking it.
D Insert the new filter cartridge (see chapter 3.5).
E Close the locking handle (3).
F Reset the BRITA cartridge exchange indicator (chapter 5)
Replacing the P 3000 refill cartridge is exactly the same as replac-
ing the P 1000. The P 3000 lasts up to 6 months with the ++-set-
ting and up to a year with the +-setting. Please take this into con-
sideration while resetting your BRITA cartridge exchange indicator.