Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
3.6
Step 6 (optional): Space-saving wall mount
to install the cartridge under the sink
(see fig. 11)
During assembly, note the installation dimensions, bending
!
radii of the hoses and dimensions of the accessories. The
system can be operated vertically and horizontally. When
using the wall mount, install vertically only!
A Attach the wall mount in place using the two matching screws
and use two wall plugs, if necessary, depending on the type of
wall.
B Engage the filter head (2) in the wall mount (1). Please use the
fixation holes (4).
1.
2.
3.
4.
(fig. 11)
10
ENGLISH
1014662-002_GA_BRITA_Tap_CE.indb 10
3.7
Step 7: Commissioning
Before use, make sure that you have followed all the steps
correctly and all the parts are fitted. Place a suitable container
under the cartridge to catch any leakages.
A Turn on the cold and hot water supplies and check the system
carefully for any leaks.
B Open the BRITA Tap and allow water to run until the filtered
water runs clear and without any bubbles (at least 2 litres).
4

Replacing the filter cartridge

If the maximum volume is reached or the cartridge has been used
for 12 months from commissioning, the BRITA Tap Cartidge Status
Indicator will flash red to remind you that the cartridge needs to be
replaced.
Read Important Notes (chapter 9) prior to exchange. After storage
and transport below 0°C, the product must be stored in the open
original packaging for at least 24 hours at the stated ambient tem-
peratures (chapter 7) for operation.
The filter cartridge can be pivoted by 90° in the wall mount
for easy removal. When the locking handle is open, the
water supply to the cartridge is interrupted and by-passing
with direct water flow from the water inlet to the outlet is
possible.
Replacing the P 1000 (see fig. 10):
A Open the locking handle (3).
B Place a suitable container under the flush hose to catch the rinse
water. Open the flush valve (2) and release pressure from the
system. Close the flush valve (2) again.
C Remove the exhausted filter cartridge (4) from the filter head (5)
– please be aware, the cartridge is firmly embedded so you can
give it a firm pull without worrying about breaking it.
D Insert the new filter cartridge (see chapter 3.5).
E Close the locking handle (3).
F Reset the BRITA Tap Cartridge Status Indicator (chapter 5).
G Open the BRITA branded lever on your BRITA Tap and rinse
through until the filtered water runs clear and without any
b ubbles (at least 2 litres).
Replacing the P 3000 refill cartridge is exactly the same as
replacing the P 1000. The P 3000 lasts up to 3400 liters with the
A-setting, up to 1700 liters with the B-setting and up 1100 liters
with the C-setting. Please take this into consideration while reset-
ting your BRITA Tap Cartridge Status Indicator.
04.04.16 11:27

Publicité

Table des Matières
loading

Table des Matières