RIGGING
This fixture may be mounted in any position, provided there is adequate room for ventilation
It is important never to obstruct the fan or vents pathway.
When selecting installation location, take into consideration lamp replacement access and routine maintenance.
Safety cables must always be used.
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted
ventilation.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his
service agent or a similar qualified person in order to avoid a hazard.
INSTALLATION INSTRUCTIONS
Installation/replacement of lamp
Do not turn the unit on if no lamp is fitted or if the lamp is burnt out.
Disconnect from mains during lamp installation
Please note: Under normal operating conditions, the housing may reach 60°C.
The lamp becomes very hot during operation. When you switch the lamp off, don't unplug it from the mains; Wait at
least for 15 minutes to let the lamp cool down otherwise you might cause a high voltage discharge, short-circuit or
burn out components on the PCB.
Make sure the installation position is stable before you fix the light. When the light is reverse hanging, make sure the
light will not fall from the truss. Pass a safety cable through the truss and bracket of the light as an extra support to
avoid the light to fall down. Don't access to the work area during mounting. Periodically check if the safety cable has
fretted away or clamp is loosened. We cannot be held responsible for inadequate fastening and installation of the
unit. It is not recommended to use the lamp constantly for more than 10 hours.
Power Supply and Signal Cable Connection
1. Mains Power connection
The exclusive plug should be used between the connection of unit and power. Please ensure that the rated voltage
and frequency are accordance with the power supply. The required input voltage and frequency are: 220-240V /
110-120V 50-60Hz
We suggest that every light has an independent switch so that you can turn on or turn off the light randomly.
Note: the ground wire (yellow/green double-color wire) must be safely connected, the electronic installation must be
in accordance with the related standards
CAUTION: When installing the device, make sure there is no highly inflammable material within a distance of
min.5m!
2. Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light.
Connect the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to
the IN socket of the next light. Ordinal to connect all the lights as below:
1
2
3
I N
IN
IN
O U T
O U T
O U T
The connection between the output of master and input of product, it's available to use the 3 pins XLR cable which
provided by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light,