Zoom adjustment ..................................................................................................... 9°/15°/20°/25°/30°
Dimensions ...........................................................................................................491 x 275 x 224mm
Weight ........................................................................................................................................ 3.4kg
INSTALLATION AND CONNECTION
This fixture may be mounted in any position, provided there is adequate room for ventilation. It is important never to obstruct
the fan or vents pathway. When selecting installation location, take into consideration lamp replacement access and routine
maintenance. Safety cables must always be used. Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his
service agent or a similar qualified person in order to avoid a hazard.
Make sure the installation position is stable before you fix the light. When the light is reverse hanging, make sure the light will
not fall from the truss, use the safety cable go through the truss and bracket of the light as a supporting, to avoid the light to
fall down. There is no entrance to the work area during mounting. Periodically check if the safety cable has fretted away or
clamp is loosened. We will not take any responsibility for damages caused by a badly installed unit.
Fixture Linking
You will need a serial data link to run light shows of one or
more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a
master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link
determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended serial data link
distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
©Copyright Lotronic 2018
PARLED100-Z
3