8.1 ALARM CORRECTION
''P1'', ''P2'', ''P3'' , and ''P4'' Sensor errors become active a few seconds after the error is detected in the
relevant sensor; The alarm signal is cut off after a few seconds after the sensors operate normally. Before
replacing the sensor It is useful to check the connections.
''HA'', ''LA'', ''HA2'', and ''LA2'' Temperature alarms are cut off immediately after the temperature reaches
normal values.
''EA'', and ''CA'' Alarms (i1F=Bal) Disconnected after digital input is disconnected.
''CA'' Alarm (i1F=PAL) is interrupted by restarting the device.
8.2 OTHER MESSAGES
pon
Keypad unlocked.
PoF
The keypad it locked.
noP
Programming mode: there is no parameter in Pr 1 level.
noA
On the screen or at Dp 2,dp 3,dp4: The selected sensor is not in use.
9. DIXELL STEPS TO BE TAKEN IN DIGITAL ALARM PROBLEMS
ALARM
MEANING
CODE
P1
Media probe reading
failure
P2
Evap probe reading
failure
in
Door open alarm
HA
High temperature
alarm
Changing the Cabinet Operating Temperature
Press and hold the "SET" button for 3 seconds. When the "C" sign on the top right is flashing, select the
desired temperature with the "up and down arrow" buttons. Then press the "SET" button.
REASON
The ambient temperature
sensor may be damaged
or broken.
The evaporator
temperature sensor may
be damaged or broken.
The door does not close or
the door switch is faulty.
An icing or cooling
problem.
www.combisteel.com
WHAT TO DO
Call technical service.
Call technical service.
Is there anything preventing the door
from closing? Otherwise, call technical
service.
Defrost if there is icing. You can put it into
Defrost mode by pressing and holding the
snowflake icon on the digital for 3
seconds . If the problem persists, call
technical service.