STEP 16: CONNECTING NATURAL GAS HOSE
TO NATURAL GAS SUPPLY LINE
See Figure 20.
 Disconnect the quick-connect coupler from the natural
gas hose.
WARNING:
Have the quick connect coupler attached to the natural
gas supply line by a certified, licensed professional.
Improper installation of the quick connect coupler can
result in a gas leak, which is a fire hazard.
To connect the natural gas hose:
 Make sure the gas is turned off at the supply line.
 Pull back the collar on the quick-connect coupler and
push the natural gas hose into coupler.
 Push the collar forward so that the hose is secured properly.
Gently pull the hose to see that it is secure.
To disconnect the natural gas hose:
 Make sure the gas is turned off at the supply line.
 Pull back and hold the collar on the quick-connect coupler.
 Remove the natural gas hose by pulling it from the quick-
connect coupler.
QUICK-CONNECT
NATURAL GAS
HOSE
Fig. 20
SUPPLY
COUPLER
NOTE: QUICK-CONNECT
COUPLER MUST BE
INSTALLED TO SUPPLY
L I N E B Y L I C E N S E D
PROFESSIONAL
ASSEMBLY
WARNING:
DO NOT smoke or use an open flame during leak test. If
a leak is present, the gas could ignite and result in serious
personal injury.
WARNING:
To avoid serious personal injury, always check for gas
leaks any time the natural gas hose is disconnected and
then reconnected.
STEP 17: TESTING VALVES AND HOSE FOR
LEAKS
 Turn all control knobs on the control panel OFF ( O ).
 Make sure the natural gas hose is properly connected to
the natural gas supply line.
 Turn on the gas supply line.
 If you hear a rushing sound, immediately shut off the gas
supply and call your gas supplier or your fire department.
This sound means there is a major leak at the connection.
 Using a clean paint brush and a 50/50 mixture of mild soap
and water, brush soapy solution over all the connections
and fittings on the grill.
 "Growing" bubbles indicate a leak. Turn off the gas at
the supply line. Disconnect the natural gas hose then
LINE
retighten all connections.
NOTE: If leaks cannot be stopped, do not try to repair.
Call for replacement parts.
 If you are not using the grill immediately after the leak
test, disconnect the natural gas hose.