Télécharger Imprimer la page

Rational iCombi Pro Manuel D'installation page 8

Masquer les pouces Voir aussi pour iCombi Pro:

Publicité

US-English
9. Place the top unit carefully on the
Combi-Duo intermediate assembly kit
[
Figure
09].
10. Fix the top unit onto the top base plate
of the Combi-Duo intermediate as-
sembly kit using at least 3 screws
[
Figure
10].
11. Mount the rubber seal around the unit
base edge of the top unit
[
Figure
11].
12. If an Ethernet cable is to be connected
to the top unit, connect the cable be-
fore the exhaust and vent pipe is
mounted for better accessibility.
13. Fix the cover for the exhaust gas pipes
with cap nuts and washers.
14. Mount the exhaust gas and ventilation
pipes [
Figure
15. Mount the flue gas stack and fix it with
a cap nut and washers [
16. Mount the shaft cover on the flue gas
stack [
Figure
Reversing the orientation of the door
handle of the bottom unit to the up
position
1. Dismantle the door handle of the bot-
tom unit: Remove the plastic cover of
the door lock on the inside of the door
by pushing the cover up on the door
and remove it [
2. Loosen the screw of the door handle
with a 5 mm Allen wrench
[
Figure
16].
3. Pull off the door handle, turn it
180 degrees and mount the door han-
dle again [
Figure
4. Mount the plastic cover again
[
Figure
18].
8 / 28
12].
Figure
13].
14].
Figure
15].
17].
80.51.377_iCombiPro-iCombiClassic_CD-G_IM_US-nord
6
Remote control
With the Combi-Duo stack, you have the
option of combining the two units to-
gether.
NOTE
Settings for remote control must be
carried out on the controlling units
For the remote control function to
work, the following steps must be set
on the controlling unit.
The controlling unit and the unit to be
controlled must be defined in advance.
a
The units are connected with an Ether-
net cable.
a
Both units are switched on and ready
for operation.
1. Press the button (Pos. 1) Setting
[
Figure
19].
2. Press the button (Pos. 2) Cooking sys-
tem [
Figure
3. Press the button (Pos. 1) Remote con-
trol [
Figure
>
The menu for remote control is
open. You can carry out the config-
uration.
4. Click the button (Pos. 2) Unit name
[
Figure
20].
>
Enter a clear unit name.
5. Click the button (Pos. 3) Unit color
[
Figure
20].
>
Select a unit color.
6. Switch the remote control button to
(Pos. 4) ON [
7. Press the button (Pos. 5) IP address of
unit to be controlled remotely
[
Figure
20].
6 | Remote control
19].
20].
Figure
20].

Publicité

loading

Ce manuel est également adapté pour:

Icombi classicLm1Lm2