MODEL
Voltage stabilizer system – Voltage – Frequency
AC Maximum Gasoline/Propane
AC Rated Gasoline/Propane
Engine model
Cylinder
Engine type
Average level of noise pressure 7mts LpA
Level guaranteed acoustic power CE-LwA, according to 2000/14/EC
Start type
Fuel tank capacity
Consumption per hour – Autonomy at 25% 50% 75% of load
Consumption per hour – propane at 25% 50% 75%
Oil capacity and grade
Transport kit
Dimensions L x W x H (cm)
Net weight / gross packaging (Kg)
Reference
Measurements of noise levels:
 The average noise pressure level at 7 meters (LpA) is the arithmetic
average of the noise level obtained from four directions and 7 meters away
from the generator.
NOTE: Different environments can result in different noise level.
Harmonized standard applied:
 ISO8528-13:2016:
Applicable EC directives:
2006/42/EC:
EU/2016/1628:
2014/30/EU:
2014/35/EU:
2000/14/EC (repealed by 2005/88 / EC):
2011/65/EU:
(EC) no-1907/2006:
NATURA 8000
SVR – 230V – 50Hz
8500/7650w
8000/7200w
GENERGY SGB460PRO
459cc
4 times OHV air-cooled
67-74dB (A)
97dB (A)
Manual/Electric
29.1L
2 l/h
0.9kg/h
1.1L SAE10W30 - SAE10W40
Yes, 9.5" rubber wheels and metallic handlebar.
775x731x678
99 / 102
15030
Generator sets driven by combustion engine.
Machinery Directive
Engine-driven machine emissions
Electromagnetic compatibility
Low voltage directive
Noise emissions directive
RoHS Directive
REACH regulation
80
2.5 l/h
3 l/h
1.5 kg/h
1.85 kg/h