INFORMATIONAL QUICK GUIDE
PRE-PLANNING QUICK GUIDE FOR INSTALLATION
Make sure you have adequate power to run the mini split system. Your Multi-zone system requires a 230V
dual pole 30-amp breaker.
1.
Determine the square foot of reach room and pick the appropriate indoor unit for that room. Oversizing
is not always better. If the room is too small and the head is too large, the unit will short cycle and not
remove the humidity from the room.
• Up to 350 sq. feet = 9,000 BTU
• Up to 500 sq. feet = 12,000 BTU
• Up to 750 sq. feet = 18,000 BTU
2.
Determine where to install the indoor head in each room.
• An exterior wall works best. If it must be on an interior wall you may need a condensate pump to
remove the condensation in the summer. This is purchased separately.
3.
Determine where the outdoor unit will be placed.
• Try to place the outdoor unit centrally to all of the indoor units.
• Keep in mind you will need to run 230v power to the unit, so try to keep it close to your electrical
panel in the house.
4.
Now that you have the location of the heads in the building and the outdoor unit outside, you will need
to figure out how long each of the line sets will be.
NOTE:
For the ultimate flexibility of your Perfect Aire Multi-Zone Mini Split, we offer the following line set
lengths and communication cables to help you achieve the perfect multi-zone system.
15 FT. Line Sets for shorter runs
DESCRIPTION
Line set 1/4 + 3/8
Line set 1/4 + 1/2
15 Ft. Line Sets with refrigerant added for longer runs
DESCRIPTION
Line set 1/4 + 3/8
Line set 1/4 + 1/2
Longer Communication Cables
DESCRIPTION
70' Communication Cable
85' Communication Cable
SKU
1DALS14-38-15
1DALS14-12-15
SKU
1DALS14-38-15-75G
1DALS14-12-15-75G
(Indoor head comes with 25ft communication cable attached by default)
SKU
1PRCOM70
1PRCOM85
(Continued)
LENGTH
REFRIGERANT AMT.
16ft./5m.
1.058oz./30g.
LENGTH
REFRIGERANT AMT.
16ft./5m.
2.65oz./75g.
LENGTH
70 ft.
85 ft.
9