INSTALLATION INSTRUCTIONS
STEP 9. CONNECTING THE DRAIN TUBE
Connect the provided drain tube to the tube on the back of the indoor unit and secure with duct tape.
STEP 10. TURNING ON THE INDOOR UNIT
1.
When the outside work has been concluded, be sure to re-check all wiring and valves.
2.
Go inside and turn on the indoor unit using the provided remote control (see figure 10.1).
3.
Set the temperature to the lowest temperature in cool mode.
4.
Wait for unit to run and assure unit blows cool air and all functions and modes are in working conditions.
STEP 11. CHECKING FOR LEAKS
Once the unit is up and running, it is important to check for refrigerant leaks.
There are two methods to check for gas leaks:
Soap and Water Method: Fill a spray bottle with dish soap and water. Spray all line set connection
1.
fittings to make sure there is no bubbling, bubbling implies there is a leak.
Leak Detector Method: When using a leak detector, please refer to the device's user manual for proper
2.
instructions.
Once confirmed that no leaks are present, replace the valve cover on the outside unit.