SAFETY & PRECAUTIONS
INSTALLATION INSTRUCTIONS
STEP 5. PREPARING THE BUNDLE
NOTE:
Double-check that the ends of the refrigerant pipes are sealed with color coded caps, preventing
dirt or foreign materials from entering the pipes. Do not remove these caps.
Before passing the refrigerant piping, drain hose and communication cable through the wall hole, you must
bundle them together to save space. Make sure that the drain hose is at the bottom of the bundle. Putting the
drain hose at the top of the bundle can cause the drain pan to overflow and backup, which can lead to fire,
water damage or both. (Figure 5.1)
1.
Double-check that the ends of the refrigerant pipes are sealed with color coded caps, preventing dirt
or foreign materials from entering the pipes. Do not remove these caps.
2.
Slowly pass the wrapped bundle of refrigerant pipes, drain hose, and communication cable through the
hole in the wall. (Figure 5.2)
3.
Hook the top of the indoor unit on the top hook of the mounting plate.
4.
Check that the unit is hooked firmly on the mounting plate by applying slight pressure to the left and
right sides of the unit. The unit should not move or shift.
5.
Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit
snaps onto the hooks along the bottom of the mounting plate.
6.
Double-check that the unit is firmly mounted by applying slight pressure to the left and the right sides
of the unit.
Large Pipe
Power Cord
18
Thermal
Insulation
Tube
Small Pipe
Drain House
(Prepared by User)
Figure 5.1