Problem
Pump does not start or stops.
(Wp)
Error-LED
is not illuminated
[ Fig. O4 ]
Charging is not possible.
Battery charge indicator
is continuously illuminated
[ Fig. O3 ]
Battery charge indicator
not illuminated [ Fig. O3 ]
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.
7. TECHNICAL DATA
Battery Pump
Max. delivery capacity
Max. pressure
Max. delivery head
Max. submersion depth
Max. media temperature
Min. water depth for operation
with foot / without foot (approx.)
Residual water level with foot /
without foot (approx.)
Weight (without Battery)
GAR_14600-56.960.02_2024-11-28.indb 11
GAR_14600-56.960.02_2024-11-28.indb 11
Possible Cause
Battery is not put completely into
the battery holder.
Battery is defective.
Product is defective.
The battery is not connected
(Lc)
(correctly).
Battery contacts are dirty.
Battery temperature is outside the
permissible charging temperature
range.
Battery is defective.
(Lc)
is
Mains plug of the charger is not
(correctly) plugged in.
Socket outlet, mains cable or
charger is defective.
Unit
Value (Art. 14600)
l/h
2000
bar
2.0
m
20
m
1.8
°C
35
mm
50 / 25
mm
25 / 5
kg
1.8
Remedy
v Put the battery completely into
the battery holder until it audibly
engages.
v Replace the battery.
v Contact the GARDENA
Service.
v Connect the battery to charger
correctly.
v Clean the battery contacts (e. g. by
connecting and disconnecting the
battery several times. Replace the
battery if necessary.
v Wait until the battery temperature is
between 0 °C and + 45 °C again.
v Replace the battery.
v Insert the mains plug into the mains
socket (completely).
v Check the mains voltage. Let the
charger be checked if necessary
by an authorised specialist dealer
or the GARDENA Service.
Value (Art. 14602)
2000
2.0
20
1.8
35
50 / 25
25 / 5
2.2
11
28.11.24 12:36
28.11.24 12:36