PUMP WILL NOT RUN
(Including: motor does not start;
fuses blow when motor starts; motor
runs but fuses blow)
PUMP RUNS BUT DELIVERS
LITTLE OR NO WATER
PUMP WILL NOT TURN OFF
PUMP STARTS TOO OFTEN
TROUBLE SHOOTING
If Trouble arises, please contact your Local Professional installer
. No power
. Incorrect voltage
. Incorrect fuses
. Defective pressure switch
. Defective wiring
. Control box malfunction
. Bound or defective pump
. Detective cable or motor winding
. Check valve
. Pump rotation wrong
. Leak in drop pipe
. Pump screen blocked
Air locked pump
. Low water level
. Worn pump
. Loose or broken motor shaft
. Pressure switch
. Low water level
. Leak in system
. Worn pump
. Pressure switch
. Check valve
. Leak in system
. Water logged tank
. Replace fuses or reset circuit breaker. Contact power com-
pany if necessary.
. Contact power company if incorrect.
. Replace with proper fuses
. Clean contact points or replace points
. Check for loose or corroded connections.
. Check wiring circuits and components, Correct wrong
wiring and/or replace defective components. Press prong
connectors to assure contact.
. Sand bound pump can sometimes be corrected by tem-
porarily reversing black and red leads in control box then
returning to normal (14 3-wire or 32). Otherwise pump
must be pulled and cleaned or repaired.
. Pump must be pulled and the motor or electrical cable
repaired or replaced.
. Reverse check valve or ensure that check valve poppett is
not being restricted in its travel because of piping being
threaded in too far.
. Properly connect one phase 3-wire unit or interchange any
two leads on three phase unit.
. Raise plpe, check for leak and replace damaged section.
. Clean screen and reset at less depth. Well may have to be
cleaned.
. Normal delivery may resume if pump is started and
Stopped at one minute intervals.
. Throttle pump output or reset pump at lower depth if well
will allow.
. Pull pump and repair or replace.
Check for damaged shaft if coupling is loose. Replace
worn or defective unit,
. Clean points or replace switch.
. Throttle pump output or reset pump at lower depth if well
will allow.
. Repair or replace tank or pipe section.
. Pull pump and repair or replace.
. Reset switch limits or replace switch.
. Remove and replace if defective.
. Repair or replace tank or pipe section.
. Clean or replace air volume control. Drain and recharge
tank.
Note: For more details on "Trouble Shooting" or additional information on motors consult Franklin Electric's "Submersible Motors Installation and
Field Service Manual."
FINAL CHECKS.
1.
Make certain all connections are properly made.
2.
Turn on current at disconnect switch. Pump should start and water should flow within a few seconds, depending
on depth of setting of pump.
3.
Checkthe amperage with an ampmeter and the voltage with voltmeter. Compare the readings with pre-installation
tests and limits shown in Electrical Information Table.
4.
It is also recommended that a resistance reading be made. Power supply MUST be disconnected to make resist-
ance readings. These tests will determine if there is damage to the cable when installing or if short or ground exists.
5.
Also check the line voltage at the control box or magnetic starter during start and run conditions. Make sure volt-
age is within limits shown on Electrical Information Table.
Page 10

Publicité

loading

Ce manuel est également adapté pour:

S serieT serie